top of page

COMMERCIAL PROJECTS

Associated British Ports 

(7th Multiple Car Storage Facility)

 

The design of a manually operated Fire Alarm System for the 7th new car storage and handling facility at the Port of Southampton.

 

The new alarm system providing an emergency fire alarm alert within the 67,130 sq m facility with the capacity to store 3,846 vehicles over six-levels.

ABP Car Storage.jpg

WORKING

DRAWINGS

RECORD

DRAWING

ZONE CHART

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

Design - Fire.png

FIRE ALARM

DESIGN

EMERGENCY

LIGHTING

DESIGN

ILLUMINATION

MODELING

ASPIRATING

DESIGN

AND

MODELING

Battery - Calcs.png

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

ABP Canary Fruit Terminal.jpg

Associated British Ports

(Canary Fruit Terminal)

 

The design of a new bespoke fire detection and alarm system protecting the entire refurbished ‘Canary Islands Fruit’ Terminal (103 & 104 berths) at Southampton Docks.

 

The facility requiring a complete building smoke protection coverage within the offices, plant and roof voids together with the entire 14,500 sq m of cool and cold storage facilities capable of operating within temperatures ranging from -2°C to +15°C.

WORKING

DRAWINGS

Drawing - Record.png

RECORD

DRAWING

Drawing - Zone Chart.png

ZONE CHART

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

Design - Fire.png

FIRE ALARM

DESIGN

EMERGENCY

LIGHTING

DESIGN

ILLUMINATION

MODELING

ASPIRATING

DESIGN

AND

MODELING

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

Draper Tools

(New Warehouse Facility)

 

The design of a fire detection and alarm system to the new Draper Tools storage warehouse facility at Test Valley Business Park in North Baddesley, near Southampton.

 

The building requiring a bespoke smoke detection solution providing coverage to the office and support areas, but to also encompass the 120,000 sq ft warehouse with detection being located at very high and inaccessible levels.

Draper Tools Warehouse.jpg

WORKING

DRAWINGS

RECORD

DRAWING

Drawing - Zone Chart.png

ZONE CHART

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

Design - Fire.png

FIRE ALARM

DESIGN

EMERGENCY

LIGHTING

DESIGN

ILLUMINATION

MODELING

VESDA - Calcs.png

ASPIRATING

DESIGN

AND

MODELING

Battery - Calcs.png

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

TestLink.jpg

Test Link Services, Poole

(Office, Warehouse & Workshop Facility)

 

Following an audit and risk assessment undertaken by the site, a initial Paper2CAD drawing transposition was undertaken to facilitate the provision of Emergency Lighting upgrade design supported with illumination modelling, to meet and in accordance with the requirements of current standards and legislation to provide and upgrade coverage to areas of the building  that had been identified as being insufficient or inadequate.

WORKING

DRAWINGS

RECORD

DRAWING

ZONE CHART

Drawing - Transposed.png

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

FIRE ALARM

DESIGN

Design - Emergency Lighting.png

EMERGENCY

LIGHTING

DESIGN

ReLux.png

ILLUMINATION

MODELING

ASPIRATING

DESIGN

AND

MODELING

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project