HEALTHCARE PROJECTS

Victoria Hospital,

Wimborne

 

Complete replacement fire alarm upgrade design with supporting documentation together with a full written Tender specification and drawings.

Victoria Hospital (Wimborne).jpg

WORKING

DRAWINGS

RECORD

DRAWING

ZONE CHART

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

Design - Fire.png

FIRE ALARM

DESIGN

EMERGENCY

LIGHTING

DESIGN

ILLUMINATION

MODELING

ASPIRATING

DESIGN

AND

MODELING

Battery - Calcs.png

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

Dorset Health Care Acorns Building.jpg

The Acorn Building, Ringwood

(Medical Equipment Store & Workshops)

 

Fire alarm upgrade design with supporting documentation together with full written Tender specification.

"As-fitted" Record drawings and zone charts.

WORKING

DRAWINGS

Drawing - Record.png

RECORD

DRAWING

Drawing - Zone Chart.png

ZONE CHART

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

Design - Fire.png

FIRE ALARM

DESIGN

EMERGENCY

LIGHTING

DESIGN

ILLUMINATION

MODELING

VESDA - Calcs.png

ASPIRATING

DESIGN

AND

MODELING

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

Shelley Road, Boscombe

(Community Healthcare Services)

Full tender package inclusive of fire alarm design drawings and complete written specification together with design supporting documentation and final system zone chart.

NHS Dorset Shelly Road.jpg

WORKING

DRAWINGS

RECORD

DRAWING

Drawing - Zone Chart.png

ZONE CHART

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

Design - Fire.png

FIRE ALARM

DESIGN

EMERGENCY

LIGHTING

DESIGN

ILLUMINATION

MODELING

ASPIRATING

DESIGN

AND

MODELING

Battery - Calcs.png

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

Nightingale House, Herbert Day Hospital.

Herbert Day Hospital, Bournemouth

(Nightingale House)

 

Inpatient mental health services residential building fire alarm upgrade design.

WORKING

DRAWINGS

RECORD

DRAWING

ZONE CHART

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

Design - Fire.png

FIRE ALARM

DESIGN

EMERGENCY

LIGHTING

DESIGN

ILLUMINATION

MODELING

ASPIRATING

DESIGN

AND

MODELING

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

Crewkerne Medical Centre,

Somerset

Emergency escape lighting upgrade with new
self-contained luminaires designed to meet the minimum lighting levels defined within
BS5266:Part 1.

CAD plans produced utilizing 'Paper2CAD' drawing transposition from existing paper building layout plans.

Crewkene Medical Centre.jpg

WORKING

DRAWINGS

RECORD

DRAWING

ZONE CHART

Drawing - Transposed.png

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

FIRE ALARM

DESIGN

Design - Emergency Lighting.png

EMERGENCY

LIGHTING

DESIGN

ReLux.png

ILLUMINATION

MODELING

ASPIRATING

DESIGN

AND

MODELING

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

Canford Heath Health Centre.jpg

Canford Heath Health Centre,

Poole

 

Fire alarm upgrade design with supporting documentation together with full written

Tender specification.

WORKING

DRAWINGS

RECORD

DRAWING

ZONE CHART

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

Design - Fire.png

FIRE ALARM

DESIGN

EMERGENCY

LIGHTING

DESIGN

ILLUMINATION

MODELING

ASPIRATING

DESIGN

AND

MODELING

Battery - Calcs.png

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

Bridport Community Hospital,

Bridport, Dorset

New emergency escape lighting design together will full illumination modelling and a written tender specification for a complete replacement of hospitals originally installed, but failed 'static invertor/central battery system.

The new emergency lighting scheme to bring the entire site in accordance with the illumination levels 

defined with BS5266:Part 1:2011.

More recently a new fire alarm zone chart.

Bridport Community Hospital.jpg

WORKING

DRAWINGS

RECORD

DRAWING

Drawing - Zone Chart.png

ZONE CHART

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

FIRE ALARM

DESIGN

Design - Emergency Lighting.png

EMERGENCY

LIGHTING

DESIGN

ReLux.png

ILLUMINATION

MODELING

ASPIRATING

DESIGN

AND

MODELING

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

Alderney Hospital (Poole).jpg

Alderney Hospital, Poole

(Phased site wide fire alarm upgrade)

 

Site wide 'networked' fire alarm design encompassing the various dementia care wards and support services buildings.

  • Admin Building & Catering Services.

  • Guernsey, Jersey & Woodlands Wards.

  • Herm & St. Brelades Wards.

WORKING

DRAWINGS

Drawing - Record.png

RECORD

DRAWING

Drawing - Zone Chart.png

ZONE CHART

PAPER2CAD

MANUALLY

MEASURED

BUILDING

SURVEY

Design - Fire.png

FIRE ALARM

DESIGN

EMERGENCY

LIGHTING

DESIGN

ILLUMINATION

MODELING

ASPIRATING

DESIGN

AND

MODELING

LOOP

&

BATTERY

CALCS

Schedule of Services Undertaken

Select a Icon to see and download a sample PDF from this project

bottom of page